Deaerator Tank Specification

  • Condition
  • New
  • Life Span
  • 15-20 years (with proper maintenance)
  • Heat Efficiency
  • 95-98%
  • Pressure
  • Up to 10 kg/cm2(g)
  • Style
  • Horizontal & Vertical cylindrical
  • Temperature
  • Up to 105C or as specified
  • Capacity
  • From 500 L to 50,000 L or more
  • Output
  • Deaerated water for boiler feed
  • Material
  • Mild Steel / SS304 / SS316
  • Part Type
  • Deaerator Tank
  • Dimension (L*W*H)
  • Custom as per requirement
  • Function
  • Removal of dissolved gases (oxygen & carbon dioxide) from boiler feedwater
  • Compliance
  • Manufactured as per ASME Section VIII / IS 2825 standards
  • Finish
  • Pre-coated / Painted / Anticorrosive coated
  • Usage
  • Boiler feedwater treatment in power plants, process industries, etc.
  • Connections
  • Flanged / Threaded as required
  • Mounting
  • Legs / Saddle support
  • Internal Fittings
  • Spray nozzles, trays, and vent for effective deaeration
  • Testing
  • Hydro-tested at 1.5 times the working pressure
  • Insulation
  • Mineral wool / Glass wool with aluminium cladding (optional)
  • Thickness
  • 3 mm to 16 mm (as per design & pressure)
 

Deaerator Tank Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 5 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Deaerator Tank



Step into the spotlight with our sizzling Deaerator Tank, a praiseworthy solution engineered for exclusive boiler feedwater treatment in power plants and process industries. Crafted from superlative Mild Steel or SS304/316, our tanks boast heroic features like anticorrosive coatings, a robust 3-16 mm thickness, and premium mineral wool insulation with elegant aluminium cladding. Designed for maximal efficiency, they deliver up to 98% heat efficiency and endure intense hydro-testing. With adherence to global standards (ASME, IS 2825) and custom dimensions, our deaerator tank promises reliability and longevity for all your industrial demands.

Versatile Utility & Directions for Use

Our Deaerator Tank is extensively used by power plants, process industries, and commercial operators to ensure optimal boiler efficiency. Its primary commercial use is to remove dissolved gases, specifically oxygen and carbon dioxide, from water before it enters the boiler. For best results, the tank should be installed according to the pressure and volume requirements, with regular monitoring of spray nozzles, trays, and vent performance for effective deaeration.


Sample Policy, Delivery, and Export Markets

We offer a flexible sample policy for our clients, tailoring samples upon request to showcase quality and design. With express shipping and reliable transport services, we ensure prompt delivery-standard shipping often completed within 2 to 4 weeks based on order size and export destination. Our product is available for freight throughout Asia, Africa, the Middle East, and Europe, supporting our global network of distributors, suppliers, and traders.


FAQ's of Deaerator Tank:


Q: How does a deaerator tank improve boiler performance?

A: A deaerator tank removes dissolved oxygen and carbon dioxide from feedwater, preventing corrosion and enhancing boiler longevity and efficiency.

Q: What materials and coatings are available for the deaerator tank?

A: Our tanks are constructed from mild steel, SS304, or SS316 and are available with pre-coated, painted, or anticorrosive finishes, tailored to project demands.

Q: When should the insulation option be selected for a deaerator tank?

A: Insulation (mineral wool or glass wool with aluminium cladding) is recommended when higher heat retention and energy efficiency are required in your operating environment.

Q: Where can the deaerator tank be customized for mounting and connections?

A: Each tank is customizable for flanged or threaded connections and can be mounted using legs or saddle supports, ensuring seamless integration into existing systems.

Q: What is the process for testing the deaerator tank before delivery?

A: All tanks undergo hydro-testing at 1.5 times working pressure to certify safety and performance, adhering to ASME Section VIII and IS 2825 standards.

Q: What are the main benefits of using a superlative deaerator tank?

A: Key benefits include higher heat efficiency (95-98%), longer service life (15-20 years), reduced maintenance costs, and compliance with international quality standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Boiler Components Category

Water Wall Panel

Water Wall Panel

Minimum Order Quantity : 1 Piece

Function : Absorb radiant heat from the furnace and protect furnace wall

Style : Other, Vertical/Horizontal

Temperature : Up to 580C

Condition : New

Life Span : 1520 years

Air Pre Heater

Air Pre Heater

Minimum Order Quantity : 1 Piece

Function : Recovers waste heat from flue gases to preheat air

Style : Other, Horizontal / Vertical

Temperature : Up to 450C inlet temperature

Condition : New

Life Span : 10 15 Years

Boiler Membrane Panel

Boiler Membrane Panel

Minimum Order Quantity : 1 Unit

Function : Heat transfer and boiler efficiency enhancement

Style : Other

Temperature : Hightemperature resistant

Condition : New

Life Span : Long

Economiser Coil Assembly

Economiser Coil Assembly

Function : Heat Recovery

Style : Other, Industrial

Temperature : Up to 350C

Condition : New

Life Span : 1015 years